Pressurization test results: Bonneville Power Administration Energy Conservation Study

Technical Report ·
DOI:https://doi.org/10.2172/6712219· OSTI ID:6712219
Results are presented of air leakage measurements in 18 single-family detached houses at the Midway substation, Hanford, Washington, performed as part of the Bonneville Power Administration's Energy Conservation Study. The change in energy consumption following various retrofit strategies is compared. Air leakage was measured in each house with the fan pressurization technique, before and after the retrofits were installed. No significant change was found in infiltration rates in those houses receiving either no retrofits or insulation only; and average reduction of 17% in leakage area was found in the houses retrofitted with storm doors and windows. There appears to be great potential for further savings in energy use from reduced infiltration, and the study is being extended to investigate this.