Result of recent weatherization retrofit projects
Conference
·
OSTI ID:5089757
Pacific Gas and Electric (PG and E) and the Bonneville Power Administration (BPA) have conducted studies in their respective service areas in order to evaluate the cost-effectiveness of certain conservation retrofits. Twenty houses in Walnut Creek, California, underwent an infiltration reduction program, similar to house doctoring. Ten of these houses also received additional contractor-installed measures. BPA retrofitted 18 houses at its Midway substation in central Washington. Retrofits made to the houses included: attic and crawlspace insulation, foundation sill caulking, storm windows and doors, increased attic ventilation, and infiltration reduction. Energy consumption and weather data were monitored before and after each set of retrofits in both projects. Leakage measurements were made by researchers from the Energy Efficient Buildings Program using blower door fan pressurization, thereby allowing calculation of heating season infiltration rates. An energy use model correlating energy consumption with outside temperature was developed in order to determine improvements to the thermal conductance of the building envelope as a result of the retrofits. Energy savings were calculated based on the results of the energy use model. As a check on these findings, the Computerized Instrumented Residential Audit (CIRA) load calculation program developed at Lawrence Berkeley Laboratory provided a theoretical estimate of the savings resulting from the retrofits. At Midway, storm windows and doors were found to save the most energy. Because the Midway houses were not very leaky at the beginning of the experiment, the infiltration reduction procedures were less effective than expected. In the Walnut Creek project, the infiltration reduction procedures did decrease the leakiness of the test houses, but the effect upon energy savings was not great.
- Research Organization:
- Lawrence Berkeley Lab., CA (USA)
- DOE Contract Number:
- AC03-76SF00098
- OSTI ID:
- 5089757
- Report Number(s):
- LBL-14734; CONF-820849-1; ON: DE82020313
- Country of Publication:
- United States
- Language:
- English
Similar Records
Results of the Bonneville Power Administration weatherization and tightening projects at the Midway substation residential community
Results of the Bonneville Power Administration weatherization and tightening projects at the Midway substation residential community
Pressurization test results: Bonneville Power Administration Energy Conservation Study
Technical Report
·
Sun Jan 31 23:00:00 EST 1982
·
OSTI ID:5269369
Results of the Bonneville Power Administration weatherization and tightening projects at the Midway substation residential community
Technical Report
·
Sun Jan 31 23:00:00 EST 1982
·
OSTI ID:6796216
Pressurization test results: Bonneville Power Administration Energy Conservation Study
Technical Report
·
Sun Nov 30 23:00:00 EST 1980
·
OSTI ID:6712219
Related Subjects
29 ENERGY PLANNING, POLICY, AND ECONOMY
291000 -- Energy Planning & Policy-- Conservation
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION
320101* -- Energy Conservation
Consumption
& Utilization-- Residential Buildings-- (-1987)
AIR INFILTRATION
BUILDINGS
CALIFORNIA
CAULKING
COST
DOORS
ENERGY CONSERVATION
ENERGY CONSUMPTION
FEDERAL REGION IX
FEDERAL REGION X
HOUSES
LEAKS
NORTH AMERICA
OPENINGS
PERFORMANCE TESTING
RESIDENTIAL BUILDINGS
RETROFITTING
STORM DOORS
STORM WINDOWS
TESTING
THERMAL INSULATION
USA
VENTILATION
WASHINGTON
WEATHER
WEATHERIZATION
WINDOWS
291000 -- Energy Planning & Policy-- Conservation
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION
320101* -- Energy Conservation
Consumption
& Utilization-- Residential Buildings-- (-1987)
AIR INFILTRATION
BUILDINGS
CALIFORNIA
CAULKING
COST
DOORS
ENERGY CONSERVATION
ENERGY CONSUMPTION
FEDERAL REGION IX
FEDERAL REGION X
HOUSES
LEAKS
NORTH AMERICA
OPENINGS
PERFORMANCE TESTING
RESIDENTIAL BUILDINGS
RETROFITTING
STORM DOORS
STORM WINDOWS
TESTING
THERMAL INSULATION
USA
VENTILATION
WASHINGTON
WEATHER
WEATHERIZATION
WINDOWS