Window selection for dual photopeak window scatter correction in Tc-99m imaging
Conference
·
· IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States)
OSTI ID:6700744
- Univ. of Massachusetts Medical Center, Worcester, MA (United States) Worcester Polytechnic Inst., MA (United States)
The width and placement of the windows for the dual photopeak window (DPW) scatter subtraction method for Tc-99m imaging is investigated in order to obtain a method that is stable on a multihead detector system for single photon emission computed tomography (SPECT) and is capable of providing a good scatter estimate for extended objects. For various window pairs, stability and noise were examined with experiments using a SPECT system, while Monte Carlo simulations were used to predict the accuracy of scatter estimates for a variety of objects and to guide the development of regression relations for various window pairs. The DPW method that resulted from this study was implemented with a symmetric 20% photopeak window composed of a 15% asymmetric photopeak window and a 5% lower window abutted at 7 keV below the peak. A power function regression was used to relate the scatter-to-total ratio to the lower window-to-total ratio at each pixel, from which an estimated scatter image was calculated. DPW demonstrated good stability, achieved by abutting the two windows away from the peak. Performance was assessed and compared with Compton window subtraction (CWS). For simulated extended objects, DPW generally produced a less biased scatter estimate than the commonly used CWS method with k = 0.5. In acquisitions of a clinical SPECT phantom, contrast recovery was comparable for both DPW and CWS; however, DPW showed greater visual contrast in clinical SPECT bone studies.
- OSTI ID:
- 6700744
- Report Number(s):
- CONF-931051--
- Conference Information:
- Journal Name: IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States) Journal Volume: 41:6Pt2
- Country of Publication:
- United States
- Language:
- English
Similar Records
Influence of phantom size, shape, and density, and collimator selection on the dual photopeak window scatter correction method
Distance-dependent restoration filtering of dual photopeak window scatter compensated SPECT images
A scatter correction method for T1-201 images: A Monte Carlo investigation
Journal Article
·
Mon Jan 31 23:00:00 EST 1994
· IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States)
·
OSTI ID:7233823
Distance-dependent restoration filtering of dual photopeak window scatter compensated SPECT images
Conference
·
Wed Nov 30 23:00:00 EST 1994
· IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States)
·
OSTI ID:6700270
A scatter correction method for T1-201 images: A Monte Carlo investigation
Journal Article
·
Sun Aug 01 00:00:00 EDT 1993
· IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States)
·
OSTI ID:5895487
Related Subjects
550601* -- Medicine-- Unsealed Radionuclides in Diagnostics
62 RADIOLOGY AND NUCLEAR MEDICINE
ACCURACY
BETA DECAY RADIOISOTOPES
BETA-MINUS DECAY RADIOISOTOPES
BODY
CALCULATION METHODS
COMPUTERIZED TOMOGRAPHY
DIAGNOSTIC TECHNIQUES
EMISSION COMPUTED TOMOGRAPHY
HOURS LIVING RADIOISOTOPES
IMAGE PROCESSING
INTERMEDIATE MASS NUCLEI
INTERNAL CONVERSION RADIOISOTOPES
ISOMERIC NUCLEI
ISOMERIC TRANSITION ISOTOPES
ISOTOPES
MONTE CARLO METHOD
NUCLEI
ODD-EVEN NUCLEI
ORGANS
PROCESSING
RADIOISOTOPES
SCATTERING
SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY
SKELETON
TECHNETIUM 99
TECHNETIUM ISOTOPES
TOMOGRAPHY
YEARS LIVING RADIOI
62 RADIOLOGY AND NUCLEAR MEDICINE
ACCURACY
BETA DECAY RADIOISOTOPES
BETA-MINUS DECAY RADIOISOTOPES
BODY
CALCULATION METHODS
COMPUTERIZED TOMOGRAPHY
DIAGNOSTIC TECHNIQUES
EMISSION COMPUTED TOMOGRAPHY
HOURS LIVING RADIOISOTOPES
IMAGE PROCESSING
INTERMEDIATE MASS NUCLEI
INTERNAL CONVERSION RADIOISOTOPES
ISOMERIC NUCLEI
ISOMERIC TRANSITION ISOTOPES
ISOTOPES
MONTE CARLO METHOD
NUCLEI
ODD-EVEN NUCLEI
ORGANS
PROCESSING
RADIOISOTOPES
SCATTERING
SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY
SKELETON
TECHNETIUM 99
TECHNETIUM ISOTOPES
TOMOGRAPHY
YEARS LIVING RADIOI