Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Economic evaluation of the nuclear turbine deaerating cycle

Conference · · Proc. Am. Power Conf.; (United States)
OSTI ID:6671619

Degradation in performance of pressurized water reactor steam generators after several years in operation has been reported in recent years. The major concern is the tube cracking caused by tube and support plate corrosion. Recent studies indicate that the level of oxygen concentration in the feedwater plays an important role in starting steam generator corrosion. The functions of a deaerator in the steam cycle is to reduce the concentration of dissolved gases, particularly oxygen, to a low level. An economic analysis has been performed to select the cycle for the pressurized water reactor plant with the installation of a deaerator to the turbine regenerative cycle.

Research Organization:
Bechtel Power Corp., Western Power Div., Norwalk, CA
OSTI ID:
6671619
Report Number(s):
CONF-860422-
Journal Information:
Proc. Am. Power Conf.; (United States), Journal Name: Proc. Am. Power Conf.; (United States) Vol. 48; ISSN PAPWA
Country of Publication:
United States
Language:
English