Dissolved oxygen in pressurized water reactor condensate and steam generator feedwater promotes corrosion of secondary cycle piping, heat exchangers and steam generators. Since dissolved oxygen in make-up water is a direct source of secondary cycle oxygen ingress, make-up water system upgrading modifications for production and storage of deoxygenated water are described. Specifications and cost estimates for the addition of a vacuum deaerator and a sealed condensate storage tank to a 300 gpm existing or new make-up water system are given.