Mark-II Data Acquisition and Trigger system
Conference
·
OSTI ID:6666117
The Mark-II Data Acquisition and Trigger system requirements and general solution are described. The solution takes advantage of the synchronous crossing times and low event rates of an electron positron collider to permit a very highly multiplexed analog scheme to be effective. The system depends on a two level trigger to operate with acceptable dead time. The trigger, multiplexing, data reduction, calibration, and CAMAC systems are described.
- Research Organization:
- Stanford Linear Accelerator Center, CA (USA)
- DOE Contract Number:
- AC03-76SF00515
- OSTI ID:
- 6666117
- Report Number(s):
- SLAC-PUB-3353; CONF-8406184-1; ON: DE84016024
- Country of Publication:
- United States
- Language:
- English
Similar Records
The data acquisition system for SLD
The data acquisition system for SLD
The data acquisition system for SLD
Conference
·
Sat Jan 31 23:00:00 EST 1987
· IEEE Trans. Nucl. Sci.; (United States)
·
OSTI ID:6724933
The data acquisition system for SLD
Conference
·
Wed Oct 01 00:00:00 EDT 1986
·
OSTI ID:7026821
The data acquisition system for SLD
Conference
·
Tue Mar 31 23:00:00 EST 1987
·
OSTI ID:6151212
Related Subjects
440104* -- Radiation Instrumentation-- High Energy Physics Instrumentation
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY
ACCELERATORS
DATA ACQUISITION SYSTEMS
DRIFT CHAMBERS
ELECTRONIC CIRCUITS
LINEAR ACCELERATORS
MEASURING INSTRUMENTS
MULTIWIRE PROPORTIONAL CHAMBERS
PERFORMANCE
PROPORTIONAL COUNTERS
PULSE CIRCUITS
RADIATION DETECTORS
STANFORD 20-GEV LINAC
TIME-OF-FLIGHT METHOD
TRIGGER CIRCUITS
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY
ACCELERATORS
DATA ACQUISITION SYSTEMS
DRIFT CHAMBERS
ELECTRONIC CIRCUITS
LINEAR ACCELERATORS
MEASURING INSTRUMENTS
MULTIWIRE PROPORTIONAL CHAMBERS
PERFORMANCE
PROPORTIONAL COUNTERS
PULSE CIRCUITS
RADIATION DETECTORS
STANFORD 20-GEV LINAC
TIME-OF-FLIGHT METHOD
TRIGGER CIRCUITS