Load turndown in a two-bed fluidized combustor

Conference ·
OSTI ID:6654398
The objective of this research is to investigate a new concept in fluidized bed design that improves load turndown capability. This design consists of a central combustion bed surrounded by an annular fluidized bed that establishes overall heat-transfer rate from the combustion bed. We have constructed a laboratory-scale version of this two-bed combustor and are testing its performance when burning three fuel forms of Illinois No. 5 coal: 3/8 inch {times} 8 mesh crushed coal, coal-water-limestone mixtures, and coal-limestone briquettes. In tests with crushed coal, we have achieved a load turndown of 12.3. These experimental results compare favorably with predictions of a computer model that simulates heat transfer in the combustor. 5 refs., 7 figs., 1 tab.
Research Organization:
Ames Lab., IA (USA)
Sponsoring Organization:
DOE/FE
DOE Contract Number:
W-7405-ENG-82
OSTI ID:
6654398
Report Number(s):
IS-M-650; CONF-890402--11; ON: DE90018022
Country of Publication:
United States
Language:
English