Evaluation of corrective reconstruction methods using a 3D cardiac-torso phantom and bull's-eye plots
- Univ. of North Carolina, Chapel Hill, NC (United States)
- Emory Univ. School of Medicine, Atlanta, GA (United States). Dept. of Radiology
The goal of the investigation was to study the effectiveness of the corrective reconstruction methods in cardiac SPECT using a realistic phantom and to qualitatively and quantitatively evaluate the reconstructed images using bull's-eye plots. A 3D mathematical phantom which realistically models the anatomical structures of the cardiac-torso region of patients was used. The phantom allows simulation of both the attenuation distribution and the uptake of radiopharmaceuticals in different organs. Also, the phantom can be easily modified to simulate different genders and variations in patient anatomy. Two-dimensional projection data were generated from the phantom and included the effects of attenuation and detector response blurring. The reconstruction methods used in the study included the conventional filtered backprojection (FBP) with no attenuation compensation, and the first-order Chang algorithm, an iterative filtered backprojection algorithm (IFBP), the weighted least square conjugate gradient algorithm and the ML-EM algorithm with non-uniform attenuation compensation. The transaxial reconstructed images were rearranged into short-axis slices from which bull's-eye plots of the count density distribution in the myocardium were generated.
- OSTI ID:
- 6650900
- Report Number(s):
- CONF-931051-; CODEN: IETNAE
- Journal Information:
- IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States), Vol. 41:6Pt2; Conference: NSS-MIC '93: nuclear science symposium and medical imaging conference, San Francisco, CA (United States), 30 Oct - 6 Nov 1993; ISSN 0018-9499
- Country of Publication:
- United States
- Language:
- English
Similar Records
Comparison of 180{degree} and 360{degree} iterative reconstruction with non-uniform attenuation compensation for Tl-201 SPECT
Bayesian SPECT lung imaging for visualization and quantification of pulmonary perfusion
Related Subjects
CHEST
SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY
HEART
ACCURACY
MATHEMATICAL MODELS
OPTIMIZATION
THREE-DIMENSIONAL CALCULATIONS
BODY
BODY AREAS
CARDIOVASCULAR SYSTEM
COMPUTERIZED TOMOGRAPHY
DIAGNOSTIC TECHNIQUES
EMISSION COMPUTED TOMOGRAPHY
ORGANS
TOMOGRAPHY
550601* - Medicine- Unsealed Radionuclides in Diagnostics