First testing of the fast kappa diffractometers at National Synchrotron Light Source and European Synchrotron Radiation Facility
Journal Article
·
· Review of Scientific Instruments; (United States)
- Department of Physics, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801 (United States)
- European Synchrotron Radiation Facility, B.P. 220, 38043 Grenoble (France)
- Riso National Laboratory, DK 4000 Roskilde (Denmark)
We present the design and first results of the performance of a new four-circle x-ray diffractometer featuring the less-common kappa'' geometry originally used on the CAD-4 instrument. This geometry permits access to all reciprocal-space settings while the mechanical supports remain entirely on one side of the beam; this is very useful for split ports on bending-magnet beamlines. Our design is able to carry heavy loads, such as a Displex-type cryostat, and operates at relatively high speeds because it uses direct drive servomotors. Considerable attention has been given to the distribution of loads which is optimized for horizontal-axis operation. A sphere of confusion of 50 [mu]m was achieved fairly easily for the mutual alignment of the axes, and this can probably be improved. Our initial tests show that accurate alignment of crystals can be achieved, and reliable measurements have been made on a number of experimental systems. Rocking curves of silicon have been measured, but these are at the limit of the setting accuracy. Arbitrary settings are achieved in about 1 s, but up to an additional 1 s settling time is needed for high accuracy work.
- DOE Contract Number:
- FG02-91ER45439
- OSTI ID:
- 6597251
- Journal Information:
- Review of Scientific Instruments; (United States), Journal Name: Review of Scientific Instruments; (United States) Vol. 66:2; ISSN 0034-6748; ISSN RSINAK
- Country of Publication:
- United States
- Language:
- English
Similar Records
Mechanical Design of a UHV Non-magnetic Kappa Diffractometer
Diffractometer-Control Software For Bragg-Rod Measurements
A new diffractometer for high energy synchrotron radiation at the elliptical multipole wiggler at the APS.
Conference
·
Mon Dec 31 23:00:00 EST 2018
·
OSTI ID:1560668
Diffractometer-Control Software For Bragg-Rod Measurements
Journal Article
·
Wed May 12 00:00:00 EDT 2004
· AIP Conference Proceedings
·
OSTI ID:20652846
A new diffractometer for high energy synchrotron radiation at the elliptical multipole wiggler at the APS.
Conference
·
Thu Aug 06 00:00:00 EDT 1998
·
OSTI ID:10703