Measurement of Compton scattering in phantoms by germanium detectors

Conference · · IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (USA)
OSTI ID:6587518
;  [1]; ;  [2]
  1. Michigan Univ., Ann Arbor, MI (USA). Medical Center
  2. Duke Univ., Durham, NC (USA). Dept. of Radiology
Quantitative Anger-camera tomography requires correction for Compton scattering. The Anger camera spectral-fitting technique can measure scatter fractions at designated positions in an image allowing for correction. To permit verification of those measurements for {sup 131}I, the authors have determined scatter fractions with a high-purity germanium (HPGe) detector and various phantom configurations. The scatter fraction values for {sup 99m}Tc were also measured and are compared to results from Monte Carlo simulation. The phantom consisted of a 22.2 cm diameter {times} 18.6 cm high cylinder filled with water and a 6 cm diameter water-filled sphere placed at various locations inside the cylinder. Radioisotope is added to either the sphere or the cylinder. The source is collimated by an Anger camera collimator and the active area of the HPGe detector is defined by a 0.6 cm diameter hole in a lead shielding mask. Corrections include accounting for the HPGe detector efficiency as a function of gamma-ray energy, the finite energy resolution of detector and the HPGe detector energy resolution compared to that for a NaI(Tl) Anger camera.
OSTI ID:
6587518
Report Number(s):
CONF-900143--
Conference Information:
Journal Name: IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (USA) Journal Volume: 37:2
Country of Publication:
United States
Language:
English

Similar Records

SU-C-201-02: Quantitative Small-Animal SPECT Without Scatter Correction Using High-Purity Germanium Detectors
Journal Article · Mon Jun 15 00:00:00 EDT 2015 · Medical Physics · OSTI ID:22486581

Influence of phantom size, shape, and density, and collimator selection on the dual photopeak window scatter correction method
Journal Article · Mon Jan 31 23:00:00 EST 1994 · IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States) · OSTI ID:7233823

Deadtime measurements with a multihole phantom: concise communication
Journal Article · Wed Dec 31 23:00:00 EST 1980 · J. Nucl. Med.; (United States) · OSTI ID:6985429