A problem-confirmation study was performed at seven sites on Chanute AFB identified in the Phase I investigation as requiring further study (Fire Training Areas 1 and 2, Landfill Nos. 1,2,3 and 4, and Building 932 Fuel Oil Storage Area). The field investigation was conducted from October 1984 to June 1985 and included the installation of 25 monitor wells, collection and analysis of groundwater samples from monitor wells, and collection and analysis of soil samples from the Building 932 Area. Analytes include VOA, TOC, TDS, Oil and Grease, EP Toxicity, Ignitibility, Xylene, Phenol, Chromium, 2,4-D and 2,4,5-TP. Based on the hydro-geologic complexity of the physical setting and findings of the sampling and analytical work, follow-on investigations were recommended at all seven sites.