skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Installation-Restoration Program. Phase 2. Confirmation/quantification. Stage 1. Problem confirmation study: Selfridge Air National Guard Base, Macomb County, Michigan. Volume 1. Final technical report, November 1984-October 1986

Technical Report ·
OSTI ID:7041055

A problem-confirmation study was performed at seven sites on Selfridge ANGB identified in the Phase I investigation as requiring further study (Southwest Sanitary Landfill, Fire Training Area 2, Fire Training Area 1, West Ramp Fuel Spill Site, Tucker Creek Landfill, Northwest Landfill, and East Ramp Fuel Spill Site). The field investigation was conducted from November 1984 to July 1985 and included installation of 25 monitor wells, collection and analysis of ground-water samples from the monitor wells, and collection and analysis of soil samples from the West and East Ramp Sites. Analytes included VOA, TOC, phenols, COD, cadmium, chromium, copper, lead, nickel, zinc, petroleum hydrocarbons, oil and grease, EP toxicity, and ignitibility. Based on the hydrogeologic complexity of the physical setting and the findings of the sampling and analytical work, follow-on investigations were recommended at all seven sites.

Research Organization:
Weston (Roy F.), Inc., West Chester, PA (USA)
OSTI ID:
7041055
Report Number(s):
AD-A-194970/0/XAB
Resource Relation:
Other Information: See also Volume 2, AD-A194 971
Country of Publication:
United States
Language:
English