Preliminary report on the baseline thermal and hydraulic performance tests of a sieve tray direct contact heat exchanger
A sieve tray direct contact heat exchanger was designed, built and then tested in a binary power cycle at the Raft River geothermal test site. A series of baseline thermal and hydraulic tests were conducted with an isobutane working fluid. The evaluation of these tests is reported. The testing of the DCHX confirmed that the repeated forming and coalescence of the working fluid drops in the sieve tray column produce excellent heat transfer performance. Tray thermal efficiencies were at or above the design value of 70% and the pinch points were well under the design goal of 1/sup 0/F (too small to be measured with installed instrumentation). From a hydraulic standpoint, the column operated at the working fluid velocities from the plate holes corresponding to the predicted condition of maximum total drop surface area (or minimum drop size) when the unit was operating near the flooding limits, or throughputs. This is the recommended working fluid hole velocity for use in designing sieve tray columns. The geothermal flow limits encountered (at flooding) corresponded roughly to the thermal rise velocity of a 1/32-inch drop. This is a drop size commonly used for specifying the terminal velocity (or continuous fluid velocity) in the design of columns for mass transfer applications.
- Research Organization:
- Idaho National Engineering Lab., Idaho Falls (USA)
- DOE Contract Number:
- AC07-76ID01570
- OSTI ID:
- 6548035
- Report Number(s):
- EGG-GTH-6101; ON: DE83005694
- Country of Publication:
- United States
- Language:
- English
Similar Records
Thermal and hydraulic performance of a sieve tray direct contact heat exchanger
Thermal and hydraulic performance of a sieve-tray direct-contact heat exchanger
Thermal and hydraulic performance tests of a sieve-tray direct-contact heat exchanger vaporizing pure and mixed-hydrocarbon Rankine-cycle working fluids
Conference
·
Mon Aug 01 00:00:00 EDT 1983
· Proc., Intersoc. Energy Convers. Eng. Conf.; (United States)
·
OSTI ID:5328632
Thermal and hydraulic performance of a sieve-tray direct-contact heat exchanger
Conference
·
Fri Dec 31 23:00:00 EST 1982
·
OSTI ID:5791673
Thermal and hydraulic performance tests of a sieve-tray direct-contact heat exchanger vaporizing pure and mixed-hydrocarbon Rankine-cycle working fluids
Technical Report
·
Mon Aug 01 00:00:00 EDT 1983
·
OSTI ID:5791707
Related Subjects
15 GEOTHERMAL ENERGY
150802* -- Geothermal Power Plants-- Power Plant Systems & Components
BINARY-FLUID SYSTEMS
DIRECT CONTACT HEAT EXCHANGERS
ENERGY SYSTEMS
FEDERAL REGION X
FLUID MECHANICS
GEOTHERMAL POWER PLANTS
Geothermal Legacy
HEAT EXCHANGERS
HYDRAULICS
IDAHO
MECHANICS
NORTH AMERICA
PERFORMANCE TESTING
POWER PLANTS
RAFT RIVER VALLEY
TESTING
THERMAL POWER PLANTS
USA
150802* -- Geothermal Power Plants-- Power Plant Systems & Components
BINARY-FLUID SYSTEMS
DIRECT CONTACT HEAT EXCHANGERS
ENERGY SYSTEMS
FEDERAL REGION X
FLUID MECHANICS
GEOTHERMAL POWER PLANTS
Geothermal Legacy
HEAT EXCHANGERS
HYDRAULICS
IDAHO
MECHANICS
NORTH AMERICA
PERFORMANCE TESTING
POWER PLANTS
RAFT RIVER VALLEY
TESTING
THERMAL POWER PLANTS
USA