skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Design review of the High Flux Isotope Reactor

Technical Report ·
OSTI ID:6534618

This report represents the results of an assessment of the design of the High Flux Isotope Reactor (HFIR), operated by the Martin Marietta Energy Systems, Inc. (MMES), located at the Oak Ridge National Laboratory (ORNL). The assessment was performed on behalf of the Assistant Secretary for Environment, Safety, and Health (ES and H) and was led by a senior member of the Office of Nuclear Safety. The report is addressed to the facility operating contractor. Thus, the report is written presuming an understanding of the facility processes, systems, and design. An executive summary is contained in Chapter 2 of the report. Chapter 3 is the general plant description. Chapters 4 through 16 contain the findings and recommendations in the areas of evaluation. Recommendations are also provided.

Research Organization:
USDOE Assistant Secretary for Environment, Safety and Health, Washington, DC. Office of Nuclear Safety
OSTI ID:
6534618
Report Number(s):
DOE/EH-0045; ON: DE88016373
Resource Relation:
Other Information: Portions of this document are illegible in microfiche products
Country of Publication:
United States
Language:
English