A bipolar monolithic preamplifier for high-capacitance SSC (Superconducting Super Collider) silicon calorimetry

Conference ·
OSTI ID:6514781
 [1];  [2];  [3]
  1. Oak Ridge National Lab., TN (USA)
  2. Tennessee Univ., Knoxville, TN (USA). Dept. of Electrical and Computer Engineering Oak Ridge National Lab., TN (USA)
  3. Tennessee Univ., Knoxville, TN (USA). Dept. of Physics

This paper describes a preamplifier designed and fabricated specifically to address the requirements of silicon calorimetry for the Superconducting Super Collider (SSC). The topology and its features are discussed in addition to the design methodology employed. The simulated and measured results for noise, power consumption, and speed are presented. Simulated an measured data for radiation damage effects as well as data for post-damage annealing are also presented. 8 refs., 7 figs., 2 tabs.