Feedback control of vertical instability in TNS

Technical Report ·
DOI:https://doi.org/10.2172/6503997· OSTI ID:6503997
Due to the unfavorable curvature of the vertical vacuum magnetic field, elongated plasmas are vertically unstable when the elongation, epsilon, becomes too large. The TNS (The Next Step) tokamak, as evolved in the Westinghouse-ORNL studies has an inside-D configuration (epsilon = 1.6, A = 5/1.25 = 4) characterized by an average decay index n approximately equal -0.75 at the plasma flux surface near the magnetic axis and is vertically unstable with a growth rate ..gamma../sub 0/ approximately 10/sup 5/ sec/sup -1/. Eddy currents produced in the vacuum vessel wall will slow this instability to growth rates ..gamma../sub 0/ approximately 10/sup 2/ sec/sup -1/ provided there are no transverse insulating gaps in the vessel wall. A matrix equation has been developed for calculating the eddy currents induced in the EF coils and their stabilizing effect. Control theory for feedback systems with and without delay time is presented and possible plasma position detectors are discussed. For a plasma current of 6.1 MA, the controller peak power requirements using separate controller circuits are approximately 1 MW depending upon EF coil configurations and time delay. This feedback system is designed to stabilize a maximum plasma excursion of 10 cm from the midplane with delay times up to 2 sec.
Research Organization:
Westinghouse Electric Corp., Pittsburgh, PA (USA). Fusion Power Systems Dept.
OSTI ID:
6503997
Report Number(s):
WFPS-TME-089
Country of Publication:
United States
Language:
English