Intercomparison of high-volume PM10 samplers at a site with high-particulate concentrations
Technical Report
·
OSTI ID:6503891
Commercially available high-volume PM10 samplers were intercompared at a site in Phoenix characterized by high concentrations of coarse particles. Over a 21-day period, Sierra Andersen 321A (SA 321A) samplers gave PM10 measurements 58% higher than the Wedding IP10 (WED) samplers and 16% higher than a SA 321A sampler that had an oil coating on the internal impaction surfaces of the inlet. WED samplers that were subjected to a simple brush-cleaning procedure after each sampling period gave PM10 results 16% higher than the WED samplers not subjected to cleaning. The oiled SA 321A sampler gave PM10 values 15% higher than the cleaned WED samplers. The results demonstrate that the SA 321A overestimates PM10 when sampling in an environment with high coarse-particle concentrations. The over collection results from pass-through of large particles, and can be minimized by oiling the internal impaction surfaces of the inlet. The WED sampler underestimates PM10 after several days of sampling in such an environment.
- Research Organization:
- Environmental Protection Agency, Research Triangle Park, NC (USA). Environmental Monitoring and Systems Lab.
- OSTI ID:
- 6503891
- Report Number(s):
- PB-87-166229/XAB; EPA-600/J-86/260
- Country of Publication:
- United States
- Language:
- English
Similar Records
Interpretation of selected EPA field data on particulate matter samplers: Rubidoux and Phoenix II
Wind-tunnel evaluation of PM10 samplers
Prototype particle stack sampler with virtual impactor nozzle and microcomputer calculating/display system. [H5 Stack Particulate Sampler/Calculator]
Journal Article
·
Fri Jan 31 23:00:00 EST 1986
· J. Air Pollut. Control Assoc.; (United States)
·
OSTI ID:5813360
Wind-tunnel evaluation of PM10 samplers
Technical Report
·
Sun Dec 31 23:00:00 EST 1989
·
OSTI ID:5897905
Prototype particle stack sampler with virtual impactor nozzle and microcomputer calculating/display system. [H5 Stack Particulate Sampler/Calculator]
Technical Report
·
Wed Jul 01 00:00:00 EDT 1981
·
OSTI ID:6291328