Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Wind-tunnel evaluation of PM10 samplers

Technical Report ·
OSTI ID:5897905
The Environmental Protection Agency (EPA) has promulgated new national ambient air quality standards for PM10 (particles smaller than 10 micrometers aerodynamic diameter). Samplers used to collect PM10 must be subjected to wind tunnel tests before they can be approved as part of a designated reference or equivalent method. Monodisperse liquid and solid particles are used over a range of particle sizes and windspeeds to characterize the sampling effectiveness and 50 percent cutpoint of candidate samplers. The paper describes an EPA wind tunnel test facility, sampler test procedures, and results of selected sampler tests with liquid and solid test particles. The agreement between wind tunnel results and observations from field measurements of ambient particulate matter is also discussed.
Research Organization:
Research Triangle Inst., Durham, NC (USA)
OSTI ID:
5897905
Report Number(s):
PB-91-146589/XAB; CNN: EPA-68-02-4550
Country of Publication:
United States
Language:
English