ABB Industrietechnik AG recently has introduced an augmented version of its Cyldeyt cylinder pressure monitoring system aimed at spark-ignited and diesel/gas, dual-fuel engines. In addition to recording and evaluating cylinder pressure as a means of assessing engine condition, the new Cyldet version now evaluates the cylinder pressure signals to provide protection against pre-ignition related damage. When pre-ignition reaches critical levels, the Cyldet computer relays alarm signals in two stages to the overriding engine control system of the power plant. On receiving the first-stage alarm signal, the engine control system is programmed to adjust one or more engine settings to eliminate preignition - a typical adjustment is to lower charge-air temperature, for example. If such measures fail to eliminate pre-ignition, in the case of a dual-fuel engine, a second alarm signal triggers a reduction in engine load or, as last resort, changeover of the engine to 100% diesel fuel charge. This paper outlines the advantages and applications of the system. 1 fig., 1 tab.