Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Determination of synchronous machine stator and field leakage inductances from standstill frequency response tests

Journal Article · · IEEE Trans. Power Syst.; (United States)
DOI:https://doi.org/10.1109/59.192973· OSTI ID:6495733
; ;  [1]
  1. Power Technologies, Inc., Schenectady, NY (US)
Generator standstill frequency response tests have been used to derive dynamic models and equivalent circuits descriptive of machine behavior. Methods developed so far have relied on having the stator leakage inductance as a given or assumed value. Use of frequency response test data with stator open and voltage applied to the field and alternately with field open and voltage applied to the stator, in each case recording voltage and current in the excited winding and voltage on the open winding, permits derivation of stator and field leakage inductance. The method is illustrated and applied to limited published standstill frequency response test data. The results indicate variation of leakage inductance depending on the frequency of the tests. The reasons for such variations are explored and hypothesized.
OSTI ID:
6495733
Journal Information:
IEEE Trans. Power Syst.; (United States), Journal Name: IEEE Trans. Power Syst.; (United States) Vol. 3:4; ISSN ITPSE
Country of Publication:
United States
Language: