A GSO depth of interaction detector for PET
Journal Article
·
· IEEE Transactions on Nuclear Science
- Kobe City Coll. of Technology (Japan)
- Hitachi Chemical Co., Ltd., Tsukuba, Ibaraki (Japan). Tsukuba Research Lab.
The authors have developed a GSO depth of interaction detector. Three GSO scintillators with different concentration of Ce were chosen and stacked along depth of interaction direction and optically coupled to a photomultiplier tube (PMT) or a position sensitive photomultiplier tube (PSPMT). In the beginning, pulse shape, light output and zero-cross time were measured to select a proper combination of GSO scintillators with different concentration of Ce. Selecting three GSO scintillators with different concentration of Ce, a single stacked GSO/PMT depth of interaction detector was fabricated for estimating the possibility of this method. Using the zero-cross time analysis, three peaks correspond to decay times of the three GSO scintillators were obtained. Finally, a GSO/PSPMT depth of interaction block detector was fabricated and tested. The block detector consists of 7 x 7 matrix of GSO scintillators which have three layers of different concentration of Ce optically coupled to a PSPMT. The pulse shape analysis was used for determination of depth of interaction direction while the Anger logic was used for transaxial and axial directions. Good separation was observed in depth of interaction direction as well as transaxial and axial directions. These results indicate that the GSO block detector may become one solution to develop a positron emission tomograph (PET) with depth of interaction detection capability.
- OSTI ID:
- 649390
- Report Number(s):
- CONF-971147--
- Journal Information:
- IEEE Transactions on Nuclear Science, Journal Name: IEEE Transactions on Nuclear Science Journal Issue: 3Pt2 Vol. 45; ISSN 0018-9499; ISSN IETNAE
- Country of Publication:
- United States
- Language:
- English
Similar Records
A BGO/GSO position sensitive block detector for a high resolution positron emission tomography with depth of interaction detection capability
Hybrid mercuric iodide (HgI/sub 2/): gadolinium orthosilicate (GSO) detector for PET
Cerium doped GSO scintillators and its application to position sensitive detectors
Conference
·
Mon Dec 30 23:00:00 EST 1996
·
OSTI ID:513180
Hybrid mercuric iodide (HgI/sub 2/): gadolinium orthosilicate (GSO) detector for PET
Conference
·
Thu Jan 31 23:00:00 EST 1985
· IEEE Trans. Nucl. Sci.; (United States)
·
OSTI ID:5083714
Cerium doped GSO scintillators and its application to position sensitive detectors
Conference
·
Tue Jan 31 23:00:00 EST 1989
· IEEE Trans. Nucl. Sci.; (United States)
·
OSTI ID:6331002