Title: Standpipe-bubbler pump level control study: 1E-3862, controlled clearance pump/system Model W. P. 7373. [LMFBR]

Technical Report ·
DOI:https://doi.org/10.2172/6474846· OSTI ID:6474846

Computer simulation results of the standpipe-bubbler pump level control system/controlled clearance pump configuration 1E-3862 using specific plan elevations are presented. Fluid level control system behavior is presented in graphical form for normal plant loading, unloading, and trip transients. Satisfactory fluid level control can be attained for this configuration with a standpipe-bubbler system.

Research Organization:
Borg-Warner Corp., Los Angeles, CA (USA). Byron Jackson Pump Div.
DOE Contract Number:
AT03-76SF98001
OSTI ID:
6474846
Report Number(s):
DOE/SF/98001-T2
Country of Publication:
United States
Language:
English