Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Features of the technological and thermotechnical operating regimes of the end heating flues on PVR system ovens

Journal Article · · Coke Chem. USSR (Engl. Transl.); (United States)
OSTI ID:6430064
The thermal and technological operating regimes of the end heating flues in PVR system coking ovens was investigated in order to determine the causes of coke collapse. Coke collapse is due to low charge bulb density and uneven heating across the charge bed. Uneven heating results in different times for completion of the coking process in different parts of the charge and a tendency to collapse in those areas in which the process is completed first. Operational parameters designed to minimize coke cake collapse are discussed.
OSTI ID:
6430064
Journal Information:
Coke Chem. USSR (Engl. Transl.); (United States), Journal Name: Coke Chem. USSR (Engl. Transl.); (United States) Vol. 5; ISSN COKCA
Country of Publication:
United States
Language:
English

Similar Records

Effect of disruptions in the oven heating regime on the coking conditions and coke quality
Journal Article · Thu Dec 31 23:00:00 EST 1981 · Coke Chem. USSR (Engl. Transl.); (United States) · OSTI ID:6418454

Variable oven chamber heating level
Journal Article · Sat Dec 31 23:00:00 EST 1983 · Coke Chem. USSR (Engl. Transl.); (United States) · OSTI ID:5508552

Temperature dynamics in the ends of coke ovens in batteries