Characterization of microchannel plate photomultipliers for plasma diagnostics

Conference ·
OSTI ID:6413105
Properties of four types of microchannel plate photomultipliers have been studied, with emphasis on applications to plasma diagnostic experiments. Detector pulse shapes, peak linear currents, pulse rate effects, and ionic feedback effects have been documented. Minimum FWHM of 210 ps was observed. Peak linear currents up to 11 A were documented.
Research Organization:
EG and G, Inc., Santa Barbara, CA (USA)
DOE Contract Number:
EY-76-C-08-1183
OSTI ID:
6413105
Report Number(s):
S-129-TP; CONF-781033-4
Country of Publication:
United States
Language:
English

Similar Records

Studies of prototype high-gain microchannel plate photomultipliers
Conference · Tue Aug 01 00:00:00 EDT 1978 · OSTI ID:6338881

Characterization of a fast, sensitive gamma detector utilizing microchannel plate photomultiplier
Conference · Tue Jan 31 23:00:00 EST 1984 · IEEE Trans. Nucl. Sci.; (United States) · OSTI ID:6920044

Electronics for microchannel photomultipliers in the LIDAR Thomson scattering diagnostic on JET
Journal Article · Sun Oct 01 00:00:00 EDT 1989 · Review of Scientific Instruments; (USA) · OSTI ID:5588912