Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Electronics for microchannel photomultipliers in the LIDAR Thomson scattering diagnostic on JET

Journal Article · · Review of Scientific Instruments; (USA)
DOI:https://doi.org/10.1063/1.1140563· OSTI ID:5588912
; ;  [1]
  1. Riso National Laboratory, DK 4000 Roskilde, Denmark (DK)
The electronics for the microchannel plate photomultiplier tubes used in the LIDAR (Light Detection and Ranging) Thomson scattering diagnostic on the JET tokamak are described. It is shown how the microchannel plate photomultiplier tubes are gated with a very small coupling between gate signal and output, and how {approx}300 V transient pulses with rise times of 230 ps are clipped to safe levels of {approx}40 V.
OSTI ID:
5588912
Journal Information:
Review of Scientific Instruments; (USA), Journal Name: Review of Scientific Instruments; (USA) Vol. 60:10; ISSN RSINA; ISSN 0034-6748
Country of Publication:
United States
Language:
English