Stress corrosion cracking of steam generator tube materials in sodium hydroxide solutions

Journal Article · · Corrosion; (United States)

Stress corroson cracking (SCC) tests were carried out on specimens of Monel 400, Inconel 600, and Sanicro 30 steam generator tubing in solutions containing 10 to 500 g NaOH/kg H/sub 2/O at 300 C for times up to 600 days. Applied stress and sodium hydroxide concentration had a significant effect on the (SCC) resistance of the three materials.

OSTI ID:
6394255
Journal Information:
Corrosion; (United States), Journal Name: Corrosion; (United States) Vol. 34:11; ISSN CORRA
Country of Publication: