Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Results of the cooldown analysis of the Swiss LCT coil

Conference · · Proc. Symp. Eng. Probl. Fusion Res.; (United States)
OSTI ID:6361831
The Cooldown of the Swiss LCT coil from 300K to 4K is analyzed with a 2-dimensional heat conduction code applied to two perpendicular planes. A dynamic model to simulate the change of helium temperature during coldown is included. Results show that the coil can be cooled down in approx. 140 hours without critical temperature gradients in any of its components.
Research Organization:
Swiss Inst for Nucl Res, Villigen, Switz
OSTI ID:
6361831
Report Number(s):
CONF-811040-
Conference Information:
Journal Name: Proc. Symp. Eng. Probl. Fusion Res.; (United States)
Country of Publication:
United States
Language:
English