Fast Flux Test Facility (FFTF) maintenance provisions

Technical Report ·
DOI:https://doi.org/10.2172/6348323· OSTI ID:6348323
The Fast Flux Test Facility (FFTF) was designed with maintainability as a primary parameter, and facilities and provisions were designed into the plant to accommodate the maintenance function. This paper describes the FFTF and its systems. Special maintenance equipment and facilities for performing maintenance on radioactive components are discussed. Maintenance provisions designed into the plant to enhance maintainability are also described.