Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Preliminary design study of underground pumped hydro and compressed-air energy storage in hard rock. Volume 9. Design approaches: CAES, Appendix C. Major mechanical equipment. Final report

Technical Report ·
OSTI ID:6322221
This appendix documents the development of the design approach for the major mechanical equipment making up the Compressed Air Energy Storage (CAES) plant surface facilities. The major mechanical equipment includes the turbine-motor/generator, compressor train, intercooler/aftercooler system, and exhaust gas recuperator. The design criteria for each of these components is interrelated with, and dependent upon, each of the other components within the major mechanical equipment group. Careful consideration of this dependency has resulted in an overall design approach which satisfies the requirements of the CAES operational cycle while providing for a conservative component design.
Research Organization:
Potomac Electric Power Co., Washington, DC (USA); Acres American, Inc., Buffalo, NY
DOE Contract Number:
AC02-77ET28013
OSTI ID:
6322221
Report Number(s):
EPRI-EM-1589(Vol.9)(App.C); ON: DE81030672
Country of Publication:
United States
Language:
English