Code for internal dosimetry (CINDY): Part 1, Conceptual representation

Technical Report ·
DOI:https://doi.org/10.2172/6305803· OSTI ID:6305803
The computer code CINDY (Computerized Internal Dosimetry Software Package) has been developed by Pacific Northwest Laboratory to address the Department of Energy (DOE) Order 5480.11 by providing the capabilities to calculate organ dose equivalents and effective dose equivalents using the approach contained in International Commission on Radiological Protection (ICRP) Publication 30. The code assists in the interpretation of bioassay data, the evaluation of committed and calendar-year doses from intake or bioassay measurement data, and the preparation of reports, consistent with revised DOE orders. The code is easy to use and is generally applicable to DOE sites. Flexible biokinetics models are used to determine organ doses for annual, 50-year, calendar-year, or any other time-point dose necessary for chronic or acute intakes. The CINDY code is an interactive computer program that prompts the user to describe the cases to be analyzed and calculates the necessary results for the type of analysis being performed. 30 refs., 13 figs., 14 tabs.
Research Organization:
Pacific Northwest Lab., Richland, WA (USA)
Sponsoring Organization:
DOE/EH
DOE Contract Number:
AC06-76RL01830
OSTI ID:
6305803
Report Number(s):
PNL-7493-Pt.1; ON: DE91002545
Country of Publication:
United States
Language:
English