Applicability of Equivalent Static Method to seismic response of piping and other components

Conference ·
OSTI ID:6282997

The Equivalent Static Method (ESM) is a simple and cost effective approach in the design of systems and components subjected to seismic loads. However, its applicability is restricted to systems which can be represented by a simple model.'' In this paper the restriction to a simple model is examined using the example of a propped cantilever, for which some codes or standards explicitly state that ESM is not applicable. By comparing ESM results for the propped cantilever with those for a regular (un-propped) cantilever, it is found that ESM can conditionally be applied to the propped cantilever configuration.

Research Organization:
Argonne National Lab., IL (United States)
Sponsoring Organization:
DOE; USDOE, Washington, DC (United States)
DOE Contract Number:
W-31109-ENG-38
OSTI ID:
6282997
Report Number(s):
ANL/RE/CP-79159; CONF-930702--40; ON: DE93015543
Country of Publication:
United States
Language:
English