Cryogenic high-heat-load optics at the advanced photon source (Invited)
- Advanced Photon Source, Argonne National Laboratory, Argonne, Illinois60439 (United States)
Cryogenically cooled silicon monochromators have found wide application at the Advanced Photon Source (APS) and other third-generation synchrotron radiation facilities. Currently, 17 insertion device beamlines at the APS are implementing cryogenic, silicon double-crystal monochromators (DCM) as the first optical element. Recently, several silicon crystal monochromators internally cooled with liquid nitrogen have been tested on the sector 1-ID undulator beamline at the APS. Rocking curves at various energies were measured simultaneously in first and third order from a Si(111) DCM in the Bragg reflection geometry at a fixed undulator gap of 11.1 mm. The crystal exhibited sub-arc second thermal broadening of the rocking curve over a first order energy range from 6.0 to 17.0 keV up to a maximum incident power of 561 W in a 2.5V{times}2.0Hmm{sup 2} beam. It has been demonstrated that cryogenic silicon monochromators can handle the highest power beams from hard x-ray undulators at the APS without significant thermo-mechanical distortion. {copyright} {ital 1997 American Institute of Physics.}
- Research Organization:
- Argonne National Laboratory (ANL), Argonne, IL
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- W-31109-ENG-38
- OSTI ID:
- 627869
- Report Number(s):
- CONF-9706157--
- Journal Information:
- AIP Conference Proceedings, Journal Name: AIP Conference Proceedings Journal Issue: 1 Vol. 417; ISSN APCPCS; ISSN 0094-243X
- Country of Publication:
- United States
- Language:
- English
Similar Records
Cryogenic high-heat-load optics at the advanced photon source
Experimental results with cryogenically cooled, thin, silicon crystal x-ray monochromator on high-heat-flux beamlines