Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Convective loss measurements at the 10 MW/sub e/ Solar Thermal Central Receiver Pilot Plant

Technical Report ·
DOI:https://doi.org/10.2172/6260485· OSTI ID:6260485

Experiments were performed at the 10 MW/sub e/ Solar Thermal Central Receiver Pilot Plant to measure the convective heat transfer from the receiver. Determining the convective loss will help reduce the uncertainty in the calculation of thermal efficiency for solar central receivers. Two types of results are presented from the data: (1) the overall receiver convective coefficient, and (2) detailed information on the local (panel) losses as a function of wind direction. The overall measured convective coefficient is also compared with predictions from correlations developed to calculate the convective coefficient. The comparison between the measured and predicted convective coefficients is good, although the correlations tend to overpredict the measured data by about 10%.

Research Organization:
Sandia National Labs., Livermore, CA (USA)
DOE Contract Number:
AC04-76DP00789
OSTI ID:
6260485
Report Number(s):
SAND-85-8250; ON: DE86006651
Country of Publication:
United States
Language:
English