Convective loss measurements at the 10 MW/sub epsilon/ solar thermal central receiver pilot plant

Conference ·
OSTI ID:5692016

Experiments were performed at the 10 MW/sub epsilon/ Solar Thermal Central Receiver Pilot Plant to measure the convective heat transfer from the receiver. Determining the convective loss will help reduce the uncertainty in the calculation of thermal efficiency for solar central receivers. Two types of results are presented from the data: (i) the overall receiver convective coefficient, and (ii) detailed information on the local (panel) losses as a function of wind direction. The overall measured convective coefficient is also compared with predictions from correlations developed to calculate the convective coefficient. The comparison between the measured and predicted convective coefficients is good, although the correlations tend to overpredict the measured data by about 10%.