The magnetohydrodynamics Coal-Fired Flow Facility

Technical Report ·
DOI:https://doi.org/10.2172/6233303· OSTI ID:6233303
In this quarterly technical progress report, UTSI summarizes the results of a multi-task research and development project directed toward the development of the technology for the commercialization of the steam bottoming plant for the MHD steam combined cycle power plant. The report covers the final test in a 2000-hour proof-of-concept (POC) test series on eastern coal, the plans and progress for the facility modifications and the conduct of the POC tests to be conducted with western coal. Results summarized in the report include chloride emissions from the particle removal (ESP/BH) processes, nitrogen and sulfur oxide emissions for various tests conditions, measurements of particulate control efficiency and management of the facility holding ponds during testing. Activities relating to corrosion and deposition probe measurements during testing and the fouling of heat transfer tubes and interaction with sootblowing cycles are summarized. The performance of both UTSI and Mississippi State University (MSU) advanced diagnostic systems is reported. Significant administrative and contractual actions are included. 2 refs., 28 figs., 7 tabs.
Research Organization:
Tennessee Univ., Tullahoma, TN (United States). Space Inst.
Sponsoring Organization:
DOE; USDOE, Washington, DC (United States)
DOE Contract Number:
AC02-79ET10815
OSTI ID:
6233303
Report Number(s):
DOE/ET/10815-156; UTSI--91-01; ON: DE92002580
Country of Publication:
United States
Language:
English