In-plant source term measurements at Fort Calhoun Station - Unit 1. Topical technical report

Technical Report ·
OSTI ID:6223390

Data obtained from an in-plant source term measurement program are presented. The objective of this program is to provide operational data that can be used in the generic evaluation of plant system design in the licensing process and for updating of the calculational models used by the NRC staff in their evaluation of radioactive waste management systems for operating pressurized water reactors. A data base is provided for radioisotope inventory in plant systems, radioactive waste management system performance, and source terms for both liquid and gaseous systems. Data presented were obtained at the Fort Calhoun Station - Unit 1, operated by the Omaha Public Power District (OPPD), located at Blair, Nebraska. In-plant measurements were conducted during the time period from August, 1976 through February 1977. This plant is the first of a planned series of six (6) operating PWR's to be studied.

Research Organization:
Idaho National Engineering Lab., Idaho Falls (USA); Allied Chemical Corp., Idaho Falls, ID (USA)
OSTI ID:
6223390
Report Number(s):
PB-284104
Country of Publication:
United States
Language:
English