Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Preliminary radiation dose assessment to WIPP waste handling personnel

Technical Report ·
DOI:https://doi.org/10.2172/6213342· OSTI ID:6213342
For CH TRU waste handling operations, the receipt and unloading of the TRUPACT is estimated to result in doses to the waste handlers and radiation control personnel of 4.46 man-rem and 0.45 man-rem, respectively. Another portion of the CH TRU waste handling operation which is estimated to result in a relatively high percentage of the total dose is the transfer of CH TRU waste containers from the hoist cage area and subsequent storage in the underground areas. The doses calculated for waste handling and radiation control personnel are 1.87 and 0.45 man-rem, respectivley. These doses represent 24% and 30% of the total CH TRU waste handling doses for these two occupational groups. For RH TRU waste handling the doses are more evenly distributed over the operational steps. The only operational segment which may be clearly considered as resulting in a large percentage of the total RH TRU waste handling dose is the emplacement operation. The series of steps comprising the emplacement operation result in 0.35 man-rem and 0.034 man-rem to the waste handlers and radiation control personnel, respectively. Annual, external wholebody doses for all waste handling operations and support activities are estimated as 11.02 man-rem for waste handlers and 2.41 man-rem for radiation control personnel. With current manpower levels of 16 waste handlers and 8 radiation control personnel, the calculated dose per worker is 0.69 rem for waste handlers and 0.30 rem for radiation control personnel. Combining the highest calculated organ dose with the external wholebody dose, the total dose to the bone per worker is 0.81 rem for waste handlers and 0.45 rem for radiation control personnel. These estimated doses fall below the Department of Energy design requirement that the combined external and internal doses be less than ones rem per person per year.
Research Organization:
Westinghouse Electric Corp., Carlsbad, NM (USA)
DOE Contract Number:
AC04-78AL05346
OSTI ID:
6213342
Report Number(s):
WTSD-TME-009; ON: DE86004330
Country of Publication:
United States
Language:
English