skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Validation of reliable, noninvasive method for determining right ventricular ejection fraction

Journal Article · · J. Nucl. Med. Technol.; (United States)
OSTI ID:6206652

Paired scintigraphic and cine CT studies were performed on 29 patients to assess the accuracy of three scintigraphic method currently available for determination of right ventricular ejection fraction (RVEF). Following a bolus injection of 30 mCi (/sup 99m/Tc)pertechnetate, a serial mode acquisition of the first transit through the heart was recorded. Processing was performed in three ways: beat-by-beat (fixed ROI), equilibrium multigated acquisition (MUGA) (variable ROI), and first-pass MUGA (variable ROI). RVEF valued determined with the first pass MUGA technique showed the best correlation with cine CT values, while those determined with the beat-by-beat or the equilibrium MUGA techniques consistently underestimated the RVEF. Thus, the scintigraphic technique using a first-pass gated format with variable ROI appears to be reliable by correlation with cine CT as an inexpensive, noninvasive method for evaluation of RV function.

Research Organization:
Univ. of Iowa Hospitals and Clinics, Iowa City (USA)
OSTI ID:
6206652
Journal Information:
J. Nucl. Med. Technol.; (United States), Vol. 16:4
Country of Publication:
United States
Language:
English