Evaluation of severe accident risks, Sequoyah, Unit 1: Appendices

Technical Report ·
OSTI ID:6188474
; ; ;  [1];  [2];  [3]
  1. Sandia National Labs., Albuquerque, NM (USA)
  2. Technadyne Engineering Consultants, Inc., Albuquerque, NM (USA)
  3. Arizona State Univ., Tempe, AZ (USA)

In support of the US Nuclear Regulatory Commission's assessment of the risk from severe accidents at commercial nuclear power plants in the US reported in NUREG-1150, the Severe Accident Risk Reduction Program has completed a revised calculation of the risk to the general public from severe accidents at the Sequoyah Power Station, Unit 1. This power plant, located in southeastern Tennessee, is operated by the Tennessee Valley Authority. The emphasis in this risk was not on determining a so-called'' point estimate of risk. Rather it was to determine the distribution of risk, and to discover the uncertainties that account for the breadth of this distribution. Off-site risks from initiating events internal to the power station were assessed. This document provides Appendices A through E for this report. Topics included are, respectively: supporting information for the accident progression analysis; supporting information for the source analysis; supporting information for the consequence analysis; risk results; and sampling information.

Research Organization:
Nuclear Regulatory Commission, Washington, DC (USA). Div. of Systems Research; Sandia National Labs., Albuquerque, NM (USA)
Sponsoring Organization:
NRC
DOE Contract Number:
AC04-76DP00789
OSTI ID:
6188474
Report Number(s):
NUREG/CR-4551-Vol.5-Rev.1-Pt.2; SAND--86-1309-Vol.5-Rev.1-Pt.2; ON: TI91006818