This report provides a method of calculating control room operator doses from postulated reactor accidents and chemical spills as part of the resolution of TMI Action Plan III.D.3.4. The computer codes contained in this report use source concentrations calculated by either TACT5, FPFP, or EXTRAN, and transport them via user-defined flow rates to the control room envelope. The codes compute doses to six organs from up to 150 radionuclides (or 1 toxic chemical) for time steps as short as one second. Supporting codes written in Clipper assist in data entry and manipulation, and graphically display the results of the FORTRAN calculations. 7 refs., 22 figs.
Research Organization:
Nuclear Regulatory Commission, Washington, DC (USA). Div. of Safety Issue Resolution; Science Applications International Corp., McLean, VA (USA)
Sponsoring Organization:
NRC
OSTI ID:
6156999
Report Number(s):
NUREG/CR-5659; SAIC--90/1054; ON: TI91005858
Country of Publication:
United States
Language:
English