Nonequilibrium sulfur capture and retention in an air cooled slagging coal combustor

Technical Report ·
DOI:https://doi.org/10.2172/614911· OSTI ID:614911
Calcium oxide injected in a slagging combustor react with the sulfur from coal combustion to form sulfur bearing particles, which are deposited on the liquid slag layer on the combustor wall. Due to the low solubility of sulfur in slag, it must be drained from the combustor to limit sulfur gas re-evolution. Analysis indicated that slag mass flow rates in excess of 400 lb/hr should limit sulfur re- evolution. The objective of this 36 month project was to perform a series of 16 one day tests to determine the factors that control the retention of the sulfur in the slag. In the present quarterly reporting period, 3 days of combustor tests were performed, bringing the total number of tests performed to 19. Two of the test were a repeat of two tests performed in the previous quarter with a high, 37% ash, Indian coal. The high slag flow rate with that coal resulted in the highest observed sulfur retention to-date, namely 20% of the injected sulfur. In the present quarter, this test was repeated with the same coal feed rate but with 75% longer period of 2.4 hours. The total mineral matter injected was 635 lb/hr, compared to only 19.7 lb/hr of sulfur, of which 75% was from injected gypsum. However, despite excellent slag flow from the previous Indian coal tests, only 5.8% of the sulfur from the gypsum reported to the slag. Since substantial amounts slag remained on the combustor walls, it is concluded that still longer duration tests are required to establish equilibrium conditions. Current efforts are focused on finding a U.S. source of high ash coal to implement additional tests.
Research Organization:
USDOE Federal Energy Technology Center, Pittsburgh, PA (United States)
Sponsoring Organization:
USDOE Assistant Secretary for Fossil Energy, Washington, DC (United States)
DOE Contract Number:
AC22-95PC95102
OSTI ID:
614911
Report Number(s):
DOE/PC/95102--T8; ON: DE97054463
Country of Publication:
United States
Language:
English

Similar Records

Nonequilibrium Sulfur Capture and Retention in an Air Cooled Slagging Coal Combustor.
Technical Report · Tue Sep 30 00:00:00 EDT 1997 · OSTI ID:643551

NONEQUILIBRIUM SULFUR CAPTURE AND RETENTION IN AN AIR COOLED SLAGGING COAL COMBUSTOR
Technical Report · Sun Mar 14 23:00:00 EST 1999 · OSTI ID:13996

Nonequilibrium Sulfur Capture and Retention in an Air cooled Slagging Coal Combustion.
Technical Report · Mon Apr 14 00:00:00 EDT 1997 · OSTI ID:611770