Nonequilibrium sulfur capture and retention in an air cooled slagging coal combustor
Calcium oxide injected in a slagging combustor react with the sulfur from coal combustion to form sulfur bearing particles, which are deposited on the liquid slag layer on the combustor wall. Due to the low solubility of sulfur in slag, it must be drained from the combustor to limit sulfur gas re-evolution. Analysis indicated that slag mass flow rates in excess of 400 lb/hr should limit sulfur re- evolution. The objective of this 36 month project was to perform a series of 16 one day tests to determine the factors that control the retention of the sulfur in the slag. In the present quarterly reporting period, 3 days of combustor tests were performed, bringing the total number of tests performed to 19. Two of the test were a repeat of two tests performed in the previous quarter with a high, 37% ash, Indian coal. The high slag flow rate with that coal resulted in the highest observed sulfur retention to-date, namely 20% of the injected sulfur. In the present quarter, this test was repeated with the same coal feed rate but with 75% longer period of 2.4 hours. The total mineral matter injected was 635 lb/hr, compared to only 19.7 lb/hr of sulfur, of which 75% was from injected gypsum. However, despite excellent slag flow from the previous Indian coal tests, only 5.8% of the sulfur from the gypsum reported to the slag. Since substantial amounts slag remained on the combustor walls, it is concluded that still longer duration tests are required to establish equilibrium conditions. Current efforts are focused on finding a U.S. source of high ash coal to implement additional tests.
- Research Organization:
- USDOE Federal Energy Technology Center, Pittsburgh, PA (United States)
- Sponsoring Organization:
- USDOE Assistant Secretary for Fossil Energy, Washington, DC (United States)
- DOE Contract Number:
- AC22-95PC95102
- OSTI ID:
- 614911
- Report Number(s):
- DOE/PC/95102--T8; ON: DE97054463
- Country of Publication:
- United States
- Language:
- English
Similar Records
Nonequilibrium Sulfur Capture and Retention in an Air Cooled Slagging Coal Combustor.
NONEQUILIBRIUM SULFUR CAPTURE AND RETENTION IN AN AIR COOLED SLAGGING COAL COMBUSTOR
Nonequilibrium Sulfur Capture and Retention in an Air cooled Slagging Coal Combustion.
Technical Report
·
Tue Sep 30 00:00:00 EDT 1997
·
OSTI ID:643551
NONEQUILIBRIUM SULFUR CAPTURE AND RETENTION IN AN AIR COOLED SLAGGING COAL COMBUSTOR
Technical Report
·
Sun Mar 14 23:00:00 EST 1999
·
OSTI ID:13996
Nonequilibrium Sulfur Capture and Retention in an Air cooled Slagging Coal Combustion.
Technical Report
·
Mon Apr 14 00:00:00 EDT 1997
·
OSTI ID:611770