NONEQUILIBRIUM SULFUR CAPTURE AND RETENTION IN AN AIR COOLED SLAGGING COAL COMBUSTOR
Calcium oxide injected in a slagging combustor reacts with the sulfur from coal combustion to form sulfur-bearing particles. They are deposited on the liquid slag layer on the combustor wall. Due to the low solubility of sulfur in slag, slag must be rapidly drained from the combustor to limit sulfur gas re-evolution. Analysis indicated that slag mass flow rates in excess of 400 lb/hr should limit sulfur re-evolution. The objective of this 42-month project was to perform a series of tests to determine the factors that control the retention of the sulfur in the slag. 36 days of testing on the combustor were completed prior to the end of this reporting period, 12/31/98. This compares with 16 tests required in the original project plan. Combustor tests in early 1997 with high (37%) ash, Indian coal confirmed that high slag mass flow rates of about 500 lb/hr resulted in retention in the slag of up to 20% of the injected sulfur content mineral matter. To further increase the slag flow rate, rice husks, which contain 20% ash, and rice husk char, which contain 70% ash, were co-fired with coal in the combustor. A series of 13 combustor tests were performed in fourth quarter of 1997 and a further 6 tests were performed in January 1998 and in the summer of 1998. The test objective was to achieve slag flow rates between 500 and 1,000 lb/hr. Due to the very low bulk density of rice husk, compared to pulverized coal, almost the entire test effort focused on developing methods for feeding the rice husks into combustor. In the last test of December 1997, a peak mineral matter, injection rate of 592 lb/hr was briefly achieved by injection of coal, rice husk char, gypsum, and limestone into the combustor. However, no significant sulfur concentration was measured in the slag removed from the combustor. The peak injection rate reached with biomass in the 1997 tests was 310 lb/hr with rice husk, and 584 lb/hr with rice husk char.
- Research Organization:
- Federal Energy Technology Center, Morgantown, WV (US); Federal Energy Technology Center, Pittsburgh, PA (US)
- Sponsoring Organization:
- US Department of Energy (US)
- DOE Contract Number:
- AC22-95PC95102
- OSTI ID:
- 13996
- Report Number(s):
- DE-AC22-95PC95102--10
- Country of Publication:
- United States
- Language:
- English
Similar Records
Nonequilibrium Sulfur Capture & Retention in an Air Cooled Slagging Coal Combustor
Nonequilibrium sulfur capture and retention in an air cooled slagging coal combustor
Nonequilibrium Sulfur Capture and Retention in an Air Cooled Slagging Coal Combustor.
Technical Report
·
Tue Apr 21 00:00:00 EDT 1998
·
OSTI ID:2088
Nonequilibrium sulfur capture and retention in an air cooled slagging coal combustor
Technical Report
·
Wed Aug 13 00:00:00 EDT 1997
·
OSTI ID:614911
Nonequilibrium Sulfur Capture and Retention in an Air Cooled Slagging Coal Combustor.
Technical Report
·
Tue Sep 30 00:00:00 EDT 1997
·
OSTI ID:643551