Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Instrumentation for localized measurements in two-phase flow conditions

Conference ·
OSTI ID:6142464
Three types of instrumentation that have been developed by EG and G Idaho, Inc., and its predecessor, Aerojet Nuclear company, at the Idaho National Engineering Laboratory to investigate two-phase flow phenomenon in a nuclear reactor at the Loss-of-Fluid Test (LOFT) facility are discussed: (a) a combination drag disc-turbine transducer (DTT), (b) a multibeam nuclear hardened gamma densitometer system, and (c) a conductivity sensitive liquid level transducer (LLT). The DTT obtains data on the complex problem of two-phase flow conditions in the LOFT primary coolant system during a loss-os-coolant experiment (LOCE). The discussion of the DTT describes how a turbine, measuring coolant velocity, and a drag disc, measuring coolant momentum flux, can provide valuable mass flow data. The nuclear hardened gamma densitometer is used to obtain density and flow regime information for two-phase flow in the LOFT primary coolant system during a LOCE. The LLT is used to measure water and steam conditions within the LOFT reactor core during a LOCE. The LLT design and the type of data obtained are described.
Research Organization:
Idaho National Engineering Laboratory (INEL), Idaho Falls, ID (United States)
DOE Contract Number:
EY-76-C-07-1570
OSTI ID:
6142464
Report Number(s):
CONF-790803-15
Country of Publication:
United States
Language:
English