A compact cyclotron C-30 for medical isotopes production

Conference · · IEEE Trans. Nucl. Sci.; (United States)
OSTI ID:6111069
The isochronous cyclotron C-30 with pole diameter 105 cm accelerates H/sup -/ particles up to 31 MeV or D/sup -/ to 16 MeV with intensities about 50 uA. The protons or deutrons extracted by stripping will be used for medical isotopes production.
Research Organization:
Institute for Nuclear Studies, Swierk
OSTI ID:
6111069
Report Number(s):
CONF-850504-
Conference Information:
Journal Name: IEEE Trans. Nucl. Sci.; (United States) Journal Volume: NS-32
Country of Publication:
United States
Language:
English