Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Development of nondestructive pull test requirements for gold wires on multilayer thick-film hybrid microcircuits

Technical Report ·
OSTI ID:6094916

Thermosonic wire bonding is used to attach 1-mil gold wires to multilayer thick-film hybrid microcircuits manufactured by the Bendix Corporation, Kansas City Division for the Department of Energy. This study was conducted to develop a realistic, nondestructive pull test limit which would detect unacceptable wire bonds and would be compatible with production processes without applying excessive stress to the wires. The effect of environmental testing on wire bond strength was also examined. A 1.5-gf nondestructive pull test limit was incorporated into production which provided an adequate screen for unacceptable bonds without significantly increasing rework time and cost for wire failures. No degradation of wire bond strengths resulted from environmental testing.

Research Organization:
Bendix Corp., Kansas City, MO (USA)
DOE Contract Number:
AC04-76DP00613
OSTI ID:
6094916
Report Number(s):
BDX-613-2859R; ON: DE83014368
Country of Publication:
United States
Language:
English