skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Leak testing at Westinghouse Hanford Company for the Fast Flux Test Facility (FFTF)

Conference ·
OSTI ID:6082210

Described leak testing applications require an arsenal of test equipment, a diverse range of testing techniques and a cadre of technical talent. A wide range helium mass spectrometer leak detector, a volume change tester and a halogen detector are employed to cover the 1 x 10/sup -8/ to 1 atm cc/sec leak rate range encountered. Leak testing techniques, equipment problems, costs, and recommendations are discussed for examination of reactor pressure boundary and other ancillary components of the FFTF.

Research Organization:
Hanford Engineering Development Lab., Richland, WA (USA)
DOE Contract Number:
AC14-76FF02170
OSTI ID:
6082210
Report Number(s):
HEDL-SA-2487; CONF-811003-3; ON: DE81030855; TRN: 82-000527
Resource Relation:
Conference: ASNT fall conference, Atlanta, GA, USA, 12 Oct 1981
Country of Publication:
United States
Language:
English