Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Solar energy system performance evaluation: Forest City Dillon, Washington, DC, January 1980-December 1980

Technical Report ·
DOI:https://doi.org/10.2172/6073792· OSTI ID:6073792

An active solar energy system consisting of 2592 square feet of single-glazed flat-plate collectors, 3200 gallons of storage liquid, and an auxiliary oil-fired boiler, is designed to supply 59% of the hot water demand for a high rise apartment building. The annual solar fraction predicted by the f-chart simulation was 37%, and the solar fraction measured was 32%. Other measures of performance, including solar savings ratio, conventional fuel savings, system performance factor, and solar system coefficient of performance, are given. The performance of the collector, storage, and domestic hot water subsystems is discussed. The operating energy of the system and weather data are given. (LEW)

Research Organization:
Automation Industries, Inc., Silver Spring, MD (USA). Vitro Labs. Div.
DOE Contract Number:
AC01-79CS30027
OSTI ID:
6073792
Report Number(s):
SOLAR/1041-81/14; ON: DE81028174
Country of Publication:
United States
Language:
English