Results of tests to evaluate the use of an in-core liquid level transducer (LLT) to measure void fraction

Technical Report ·
OSTI ID:6071973
The results are presented of tests conducted at the LOFT Test Support Facility (LTSF) using a Liquid Level Transducer (LLT) to measure void fraction. The LLT used was an in-core transducer S/N 445. The purpose of these tests was to evaluate the LLT as a void fraction measuring instrument. Tests were conducted at atmospheric pressure and room temperature by partially filling a test column with demineralized water and bubbling oxygen from the bottom. The liquid level was measured with a metric rule on the side of the test column before any gas injection.
Research Organization:
Idaho National Engineering Lab., Idaho Falls (USA)
DOE Contract Number:
EY-76-C-07-1570
OSTI ID:
6071973
Report Number(s):
LTR-141-103
Country of Publication:
United States
Language:
English