Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Pulsed power performance of the new RLA (Recirculating Linear Accelerator)

Conference ·
OSTI ID:6018300

The Recirculating Linear Accelerator (RLA) is returning to operation with a new electron beam injector and a modified accelerating cavity. Upon completion of our experimental program the RLA will capture the injected beam on an IFR guiding plasma channel in either a spiral or a closed racetrack drift tube. The relativistic beam will be efficiently recirculated for up to four passes through two or more accelerating cavities, in phase with the ringing cavity voltage waveforms, and thereby increased in energy to 10 MeV before being extracted. The inductively isolated four-stage injector was designed to produce beam parameters of 4 MeV, 10--20 kA, and 40--55 ns FWHM. The three-line radial cavity is being modified to improve the 1-MV accelerating voltage pulse shape while an advanced cavity design study is in progress. The actual versus predicted pulsed-power performance of the RLA injector and cavity and the associated driving hardware will be discussed in this paper.

Research Organization:
Sandia National Labs., Albuquerque, NM (USA)
Sponsoring Organization:
DOD; DOE; Department of Defense, Washington, DC (USA); USDOE, Washington, DC (USA)
DOE Contract Number:
AC04-76DP00789
OSTI ID:
6018300
Report Number(s):
SAND-90-2883C; CONF-910640--1; ON: DE91004723
Country of Publication:
United States
Language:
English