Develop and test fuel-cell-powered on-site integrated total-energy systems. Phase III. Full-scale power plant development. 6th quarterly report, May-July 1982
Technical Report
·
OSTI ID:6012744
Satisfactory performance is reported for the three 12-cell sub-stacks of the 5 kW stack rebuild. Early general conclusions are presented from an economic study of OS/IES by subcontractor Arthur D. Little, Inc. Results are reported on a successful 700-hour test of a 3-cell stack in the full-sized configuration (0.33 m x 0.56 m). Construction of a 5-kW-equivalent methanol/steam reformer based on a commercial shell-and-tube heat exchanger was completed. Several test runs are summarized. Preliminary conclusions are presented on the technical and economic aspects of fuel cell/HVAC interaction for OS/IES as developed by the subcontractor, Trane Company. Physical data are presented on several dense graphite materials which are candidates for gas-distribution plates. Performance of a new cathode catalyst is reported.
- Research Organization:
- Engelhard Corp., Edison, NJ (USA). Engelhard Industries Div.
- DOE Contract Number:
- AI01-80ET17088
- OSTI ID:
- 6012744
- Report Number(s):
- DOE/NASA/0241-6; NASA-CR-168021; ON: DE83012979
- Country of Publication:
- United States
- Language:
- English
Similar Records
Develop and test fuel-cell-powered on-site integrated total-energy systems: Phase III, full-scale power plant development. 5th quarterly report, February-April, 1982
Develop and test fuel-cell-powered on-site integrated total-energy systems: Phase III, full-scale power-plant development. Fourth quarterly report, November 1981-January 1982
Cell module and fuel conditioner development. 7th quarterly report, April-June 1981
Technical Report
·
Tue Nov 02 23:00:00 EST 1982
·
OSTI ID:6867846
Develop and test fuel-cell-powered on-site integrated total-energy systems: Phase III, full-scale power-plant development. Fourth quarterly report, November 1981-January 1982
Technical Report
·
Mon Jun 21 00:00:00 EDT 1982
·
OSTI ID:5084546
Cell module and fuel conditioner development. 7th quarterly report, April-June 1981
Technical Report
·
Wed Jul 01 00:00:00 EDT 1981
·
OSTI ID:6079080
Related Subjects
30 DIRECT ENERGY CONVERSION
300501* -- Fuel Cells-- Design & Development
300504 -- Fuel Cells-- Applications
ACID ELECTROLYTE FUEL CELLS
ALCOHOLS
CATALYSTS
CHEMICAL REACTIONS
COGENERATION
DESIGN
DEUS
DIRECT ENERGY CONVERTERS
ELECTROCATALYSTS
ELECTROCHEMICAL CELLS
ENERGY SYSTEMS
FUEL CELLS
FUEL SYSTEMS
HYDROGEN COMPOUNDS
HYDROXY COMPOUNDS
INORGANIC ACIDS
METHANOL
ON-SITE POWER GENERATION
ORGANIC COMPOUNDS
PERFORMANCE TESTING
PHOSPHORIC ACID
POWER GENERATION
POWER RANGE 1-10 KW
REFORMER PROCESSES
STEAM GENERATION
STEAM REFORMER PROCESSES
TESTING
TOTAL ENERGY SYSTEMS
300501* -- Fuel Cells-- Design & Development
300504 -- Fuel Cells-- Applications
ACID ELECTROLYTE FUEL CELLS
ALCOHOLS
CATALYSTS
CHEMICAL REACTIONS
COGENERATION
DESIGN
DEUS
DIRECT ENERGY CONVERTERS
ELECTROCATALYSTS
ELECTROCHEMICAL CELLS
ENERGY SYSTEMS
FUEL CELLS
FUEL SYSTEMS
HYDROGEN COMPOUNDS
HYDROXY COMPOUNDS
INORGANIC ACIDS
METHANOL
ON-SITE POWER GENERATION
ORGANIC COMPOUNDS
PERFORMANCE TESTING
PHOSPHORIC ACID
POWER GENERATION
POWER RANGE 1-10 KW
REFORMER PROCESSES
STEAM GENERATION
STEAM REFORMER PROCESSES
TESTING
TOTAL ENERGY SYSTEMS